Surge protection in Fabric: one workspace can't take it all

Fabric surge protection on two levels, capacity and workspace (generally available since November 2026). How the 24-hour background percentage triggers rejection, how to pick thresholds from the Capacity Metrics app, a worked F64 example of a workspace cap in CU hours, the three workspace states, unblocking and forgiving, and the limits.

Short answer: surge protection keeps a Fabric capacity usable for people opening reports when background jobs (refreshes, pipelines, notebooks) run hot. It works on two levels. Capacity level: when the capacity's 24-hour background percentage reaches your rejection threshold, new background operations are rejected until it falls below your recovery threshold. Workspace level (generally available since November 2026): each workspace may use at most a set percentage of the capacity's CU over a rolling 24 hours; a workspace that goes over is blocked. Admins can mark workspaces Mission critical (exempt from the workspace cap) or Blocked by hand, and unblock them with or without forgiving the usage already counted.

Shared capacities have one classic failure: a team in one workspace starts a heavy reload at 9:00, the capacity's smoothed usage climbs past its limits, and by 10:00 the finance reports in another workspace are slow or refused. Nobody in finance did anything wrong. Surge protection lets an admin decide in advance who gives way.

How do the two levels differ?

Capacity level
  • watches the whole capacity
  • rejects new background jobs early, before deep throttling hits everyone
Workspace level
  • watches each workspace
  • blocks the one that used more than its share of the day
Two levels of surge protection

Capacity-level protection is a brake for everyone; workspace-level protection points at the workspace that caused the load. Most shared capacities want both.

How do you size a workspace cap?

The cap is a percentage of what the capacity provides in 24 hours. An F SKU provides as many CU seconds per second as its number, so a day holds that number times 24 CU hours:

CapacityCU hours per day5% cap10% cap20% cap
F2482.44.89.6
F81929.619.238.4
F641,53676.8153.6307.2
What a workspace cap means in CU hours per rolling 24 hours

On an F64 with a 10% cap, a single workspace may use 153.6 CU hours in any 24-hour window (64 × 24 = 1,536; 10% of that). Ten busy workspaces at 10% each could still fill the capacity, so pair the cap with capacity-level thresholds.

How do you choose the capacity thresholds?

Open the Capacity Metrics app, Compute page, and read three charts: Background rejection (the 24-hour background percentage), Interactive rejection and Utilization. Microsoft's own starting rules:

What the charts showRejection thresholdRecovery threshold
Background averages 50%, peaks at 60% and 75%, low 40%; interactive rejection passed 100% at the 75% peakbetween 60% and 75%between 40% and 60%
Background steady around 35% (within 5%), interactive peak 80%a little above 40%, below 60%about 35%
80% to 90% of utilisation is background workbackground limits may not help(isolate workloads instead)
Reading the charts into thresholds

Then: admin portal, Capacity settings, pick the capacity, Surge protection, set Background Operations on, enter both thresholds and Apply.

How do you set the workspace cap?

  1. OneLake catalog, Govern, Capacities, select the capacity.
  2. Under Surge protection, turn Workspace consumption on.
  3. Set the Rejection Threshold (the percentage per workspace) and Block (indefinitely, or for a number of hours).
  4. In the Workspaces table, use the gear in Actions to set any workspace to one of three states:
StateCap appliesAuto-blockUse for
Availableyesyesmost workspaces (the default)
Mission criticalnonothe finance close, the executive reports
Blockedn/an/aa runaway workspace, or one paused on purpose
The three workspace states

A Blocked workspace rejects all interactive and background operations. Mission critical lifts the workspace cap, not the capacity's own limits: when the whole capacity runs out of CU, throttling still reaches that workspace.

  1. Turn on notifications: a banner for everyone in the workspace while it is blocked, and email to the workspace contacts. They fire when a workspace approaches its threshold, is blocked, is unblocked or recovers.

How does a blocked workspace come back?

By itself, when the block duration ends or when its rolling 24-hour usage drops back under the cap; Fabric checks again at regular intervals. Or an admin selects Unblock in Capacity settings, reviews the usage and confirms. When unblocking by hand, the admin can also forgive recorded usage, which lowers the rolling total so the workspace is not blocked again straight away. Marking it Mission critical unblocks it too.

Unblocking lets new operations start. It does not cancel, restart or rebill operations that were already running.

What goes wrong?

  • Raising the limit and expecting the block to lift. It does not. Change the limit first, then unblock.
  • Blocked again right after the block ended. The 24-hour window does not reset when a block ends; without forgiveness, the old usage still counts.
  • Treating the cap as exact. Usage is checked every five minutes, so a workspace can pass its limit before it is stopped.
  • Some items ignore the workspace cap: Dataflow Gen1, paginated reports, scorecards, graph models and Activator are not covered yet, and Dataflow Gen2 editing is not either (its refreshes are).
  • Autoscale. Compute billed through autoscale is not counted toward workspace limits, and capacity-level protection does not block autoscale operations.
  • Running jobs. Capacity-level protection only rejects new background jobs; jobs in progress keep running and keep adding usage.
  • Other SKUs. Surge protection works on Fabric (F) SKUs only.

Where can you check this?

Where do you start?

Open the Capacity Metrics app and look at the last two weeks of the Background rejection chart before changing anything. Mark the two or three workspaces that must never stop as Mission critical, start the workspace cap generously (20% on a shared capacity) and tighten it once you see who hits it. Finding the operation behind a capacity spike shows how to read those charts, and Fabric capacity units and F SKUs explains what a CU is.